Analytical Method Development and Validation for the Simultaneous Estimation of Ramucirumab and Paclitaxel by RP-HPLC Technique

Sama Divya Jyothi1*, Gope Edward Raju2, Kandregula Uma Maheswari3, Doonaboyina Raghava4, Kavala Nageswara Rao5
Department of Pharmaceutical Analysis, K.G.R.L College of Pharmacy, Bhimavaram-534201, Andhra Pradesh, India

A  B S T R A C T
High performance liquid chromatography is at present one of the most sophisticated tool of the analysis. The estimation of Ramucirumab and Paclitaxel was done by RP-HPLC. The Phosphate buffer was pH 4.5 and the mobile phase was optimized with consists of Methanol: Phosphate buffer mixed in the ratio of PH 4.5(20:80 v/v). Kromosil C18 Column (250mm x 4.6mm) 5µg or equivalent chemically bonded to porous silica particles was used as stationary phase. The detection was carried out using UV detector at 254 nm. The solutions were chromatographed at a constant flow rate of 1 ml min-1. The linearity range of Ramucirumab and Paclitaxel were found to be from 100-500 mg/ml of Ramucirumab and 1-5mg/ml of Paclitaxel. Linear regression coefficient was not more than 0.999.The values of % RSD are less than 2% indicating accuracy and precision of the method. Ramucirumab %RSD 0.2 and Paclitaxel %RSD 0.6 Intermediate precision for Ramucirumab %RSD 0.2 and Paclitaxel %RSD 0.1. The percentage recovery varies from 98-102% of Ramucirumab and Paclitaxel. LOD and LOQ were found to be within limit. The results obtained on the validation parameters met ICH and USP requirements .it inferred the method found to be simple, accurate, precise and linear. The method was found to be having suitable application in routine laboratory analysis with high degree of accuracy and precision.

Keywords: Kromosil C18, Ramucirumab and Paclitaxel, RP-HPLC

Scroll To Top