Saturday , 20 April 2024

Tag Archives: Acyclovir

Fabrication and evaluation of acyclovir Transdermal patches by using different polymer compositionps: In-Vitro

R. Venu Priya*1 and Vinesh Kumar2 1Research Scholar, Sun Rise University, Alwar, Rajasthan, India. 2Department of Pharmacy, Sun Rise University, Alwar, Rajasthan, India. A B S T R A C T Transdermal drug delivery systems are becoming more popular in the field of modern pharmaceutics. Different matrix-type transdermal films containing acyclovir was formulated with an objective to study the effect ... Read More »

Development and Validation of a RP-HPLC Method for the Determination of Acyclovir in Transdermal Patches

R. Venu Priya1 and Vinesh Kumar2 1Research Scholar, Sun Rise University, Alwar, Rajasthan, India. 2Department of Pharmacy, Sun Rise University, Alwar, Rajasthan, India. A B S T R A C T The present report describes a rapid and sensitive High Pressure Liquid Chromatography (HPLC) method with UV detection to quantify acyclovir in transdermal patches. After sample preparation with diluent separation ... Read More »

Preparation and Evaluation of Mucoadhesive Opthalmic Niosomes of Acyclovir Using Chitosan and Carbopol

Dr. Raghvendra1*, Pragya Sharma1, Nidhi Dhama2 1Assistant Professor, Department of Pharmaceutics, Aligarh College of Pharmacy, Aligarh, U.P., India, 202001 2Assistant Professor, Department  of Pharmaceutics, Translam Institute of Pharmaceutical Education and Research, Meerut, U.P. India, 250001 A B S T R A C T Niosomes have been reported as a possible approach to deliver the drug to ophthalmic cavity. Niosomes were ... Read More »

Analytical Method Development and Validation for the Simultaneous Estimation of Acyclovir and Hydrocortisone by RP-HPLC Method in Bulk and Tablet Dosage Form

CH. Shankar*, B. Rajesh Department of Pharmaceutical Analysis, Vikas College of Pharmaceutical Sciences, Rayanigudem, Suryapet, Nalgonda, Telangana, India-508376 A B S T R A C T The chromatographic conditions were successfully developed for the separation of Acyclovir and Hydrocortisone by using Agilent C18  Column (250mm x 4.6mm)5µm, flow rate was 1ml/min, mobile phase ratio was  Phosphate buffer PH 2.5:Methanol (65:35 ... Read More »

Acyclovir, Β-Cyclodextrin Complexed Matrix Tablets: Preparation and Evaluation

Suvarnamma B*, Naresh G, Hindustan Abdul Ahad, Sreedhar V, Rajesh Pavan A  Department of Pharmaceutics, Balaji College of Pharmacy, Ananthapuramu, AP, India Abstract The Study was endeavored with a plan to characterize β-cyclodextrin complexed controlled release matrix tablets of Acyclovir and it’s in vitro appraisal using guar gum as release frustrating agent. Preformulation study was done and results composed for ... Read More »

Scroll To Top